Bulging is usually caused by overcharging, excessive charge voltage, a blocked safety valve or an internal short. It is irreversible and a safety risk. Stop using it immediately, isolate it, and send photos with your usage and charge parameters. We will assess it under the warranty terms.
14
Is reduced capacity and hard starting in winter normal?
Yes. Lead-acid capacity drops about 20 percent at 0 degrees Celsius and about 50 percent at minus 18 degrees, while higher oil viscosity increases cranking resistance. Check the charging system before winter, keep the battery fully charged and choose a higher CCA model.
15
The battery cannot recover after a deep discharge. What can be done?
If open-circuit voltage falls below 10.5V on a 12V unit and remains there for over 30 days, irreversible sulfation is likely. Try a low-current recovery charge at 0.05C for 24 to 48 hours; if capacity remains below 80 percent, replacement is advised. Fit low-voltage protection to avoid discharging below 50 percent depth of discharge.
16
How should the charge voltage and current be set?
General guidance: charge current at 0.1C to 0.2C, cycle charge voltage 14.4 to 14.8V and float 13.5 to 13.8V for 12V maintenance-free, with temperature compensation of about 3mV per cell per degree Celsius away from 25. For series strings, multiply the per-unit voltage by the number of units.
17
Is significant heating during charging normal?
Slight warming is normal, but a noticeably hot case above 45 degrees Celsius is abnormal, usually caused by excessive charge voltage or current, an internal short or high ambient temperature. Stop charging immediately and report the charge parameters and infrared temperature photos.
18
The battery will not hold charge and runtime is short. What now?
Common causes are sulfation from chronic undercharging, excessive depth of discharge, low charge voltage settings or an internal short in one unit. Please provide charge parameters, discharge current and measured runtime so we can determine whether it is a usage or quality issue.
19
The battery will not accept charge. What should I do?
Check in order: charger output voltage, reversed polarity, whether open-circuit voltage is too low and has triggered protection, oxidized or loose terminals, and ambient temperature below 0 degrees Celsius. Deeply discharged batteries should first be revived with a low-current recovery charge.
20
Is a low voltage on arrival normal?
Maintenance-free batteries ship fully charged, so a 12V unit should read above 12.6V open-circuit and a 2V cell above 2.10V. Readings below 12.4V may result from long transit or storage. Please record and report them and we will guide recharge or handle under warranty.
21
What if batteries arrive damaged or leaking?
Do not touch the electrolyte directly. Isolate the damaged units and wear protective gloves and goggles, then take photos and videos including packaging, carton marks, damage and serial numbers, and contact us within 48 hours. Neutralize spills with baking soda and never pour them into drains.
22
How should batteries be maintained during long-term storage? How often do they need recharging?
Store in a dry, ventilated, light-proof environment; lead-acid batteries have high self-discharge, so they must be recharged to full every 1-2 months; long-term storage in a discharged state causes permanent sulfation and scrapping, which is not covered by warranty.
23
What are the common failure symptoms of the batteries?
Capacity decline, low terminal voltage, inability to charge, swollen case, and acid leakage/corrosion; zero voltage is usually caused by broken terminal welding or an internal open circuit.
24
Which inverters are supported?
Most mainstream solar inverters are supported; please contact us to confirm specific models.